TORQMAX F5 Drive v3.xx Parameters Table
iControl AC
9
DG20 Raw Pattern - -
-10.00-
10.00
VDC 0.00
DG21
Processed
Pattern
--
-10.00-
10.00
VDC 0.00
DG30 Peak DC Volts - - 0-1500 Volts 0
DG31 Peak Current - -
-3200.0-
3200.0
Amps 0.0
DG32 Peak Speed - - 0-2500 ft/min 0
DG33 Raw Pretorque - -
-10.00-
10.00
VDC 0.00
DG34 Post Pretorque
- - -10.00-
10.00
VDC 0.00
DG35
Analog
Output 1
- - -10.00-
10.00
VDC 0.00
DG36
Analog
Output 2
- - -10.00-
10.00
VDC 0.00
DG37
Heatsink
Temperature
- - 0-120
Degree
Celsius
0
DG38
Motor
Temperature
--0: T1-T2
Closed-150
Degree
Celsius
0
DG39
Carrier
Frequency
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
0
1
2
3
4
2kHz0
DG40 Electric Power -
- -320.0-
320.0
kW 0.0
DG41 Motor Power -
- -320.0-
320.0
kW 0.0
DG42 Braking Energy - - 0-65535 kWh 0
DG43
Power On
Counter
-
-
0-65535 hr 0
DG44
Run Time
Counter
-
-
0-65535 hr 0
DG45
Overload
Counter
-
-
0-100 % 0
DG46 Drive Load - 0-500 % 0
DG47 Peak Load - - 0-500 % 0
DG50 Elevator Speed - - 0-2000 ft/min 0
DG51 Mode See Section 6.16 - 0 - 0
DG52 Active Profile
None
Inspection
High Speed
One Floor
Emergency
Correction
Emergency Slowdown
0
1
2
4
8
16
32
0-0
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para. Name Setting Num Range Units Default