9-49
Magnetek HPV900 Series 2 Parameters Quick Ref-
iControl AC
9
Configure C0
C1 User Switches
Spd Command Src Speed Command Source - Analog input
Multi-step
Serial
Analog
input
Analog
input
Run Command Src Run Command Source - External TB
Serial
Serial+extern
Analog
input
Analog
input
Hi/Lo Gain Src High / low gain change switch source - External TB 1
Serial
Internal
Internal
Speed Reg Type Chooses speed regulator - Elev spd reg
Pi speed reg
Elev spd
reg
Elev spd
reg
Motor Rotation Allows user to reverse direction of motor rota-
tion
-Forward
Reverse
Forward
Spd Ref Release Determines when speed reference release is
asserted
-Reg release
Brake picked
Reg
release
Cont Confirm Src Enables external logic input for contactor con-
firmation.
-None
External TB
None External
TB
Pre Torque Source Enables and determines the source of the pre
torque command
-None
Analog input
Serial
Analog
input
Analog
input
Pre Torque Latch Determines if analog pre-torque command is
latched
-Not latched
Latched
Not
latched
PT torq Latch Clck Determines source of pre torque latch control
(if used)
-External TB
Serial
External
tb
Fault Reset Src Fault reset source - External TB
Serial
Automatic
External
tb
Overspd Test Src Determines external logic source to trigger
overspeed test
-External TB
Serial
External
tb
Brake Pick Src If drive controls mechanical brake, determines
source of brake pick command
- Internal
Serial
Internal
Brake Pick Cnfrm Enables a logic input to use for brake pick con-
firmation
-None
External TB
None
Brake Hold Src If drive controls mechanical brake, determines
source of brake hold command
- Internal
Serial
Internal
Ramped Stop Sel Selects normal stop or torque ramp down stop - None
Ramp on stop
Ramp on
stop
Ramp on
stop
Ramp Down En Src Determines the source that signals the torque
ramp down stop (if used)
-External TB
Run logic
Serial
Run logic Run logic
Brk Pick Flt Ena Brake pick fault enable - Enable
Disable
Disable
Brk Hold Flt Ena Brake hold fault enable - Enable
Disable
Disable
Ext Torq Cmd Src When Speed Reg Type = External Reg, sets
the source of the torque command
-None
Serial
None
Table 9.7 Magnetek AC Drive Parameters Table
#
Operator
Display
Parameter Description Unit
Setting
Range
MCE
Defaults
Field
Setting