9-56 Manual # 42-02-2223
Reference
DSPR TIME Drive Standby Power reduction Time. Deter-
mines how long drive will remain energized
with motor field current at standby amps
before completing drive shutdown. Used only
when DPSR ENABLE (C1) set to Enable
min 0 – 500 10 10
A2 S-Curves Submenu
ACCEL RATE 0 Acceleration rate Limit ft/s2 0.00 – 7.99 7.99 7.99
DECEL RATE 0 Deceleration Rate limit ft/s2 0.00 – 7.99 7.99 7.99
ACCEL JERK IN 0 Rate of increase in acceleration up to ACCEL
RATE when increasing elevator speed ft/s3
0.0 – 29.9 0.0 0.0
ACCEL JERK OUT 0 Rate of decrease in acceleration to zero when
approaching contract elevator speed.
ft/s3 0.0 – 29.9 0.0 0.0
DECEL JERK IN 0 Rate of increase in deceleration to DECEL
RATE when decreasing elevator speed
ft/s3 0.0 – 29.9 0.0 0.0
DECEL JERK OUT 0 Rate of decrease in deceleration to zero when
slowing the elevator to leveling speed.
ft/s3 0.0 – 29.9 0.0 0.0
ACCEL RATE 1 Acceleration rate Limit ft/s2 0.00 – 7.99 7.00 7.00
DECEL RATE 1 Deceleration Rate limit ft/s2 0.00 – 7.99 3.00 3.00
ACCEL JERK IN 1 Rate of increase in acceleration up to ACCEL
RATE when increasing elevator speed
ft/s3 0.0 – 29.9 8.0 8.0
ACCEL JERK OUT 1 Rate of decrease in acceleration to zero when
approaching contract elevator speed.
ft/s3 0.0 – 29.9 8.0 8.0
DECEL JERK IN 1 Rate of increase in deceleration to DECEL
RATE when decreasing elevator speed
ft/s3 0.0 – 29.9 8.0 8.0
DECEL JERK OUT 1 Rate of decrease in deceleration to zero when
slowing the elevator to leveling speed.
ft/s3 0.0 – 29.9 8.0 8.0
ACCEL RATE 2 Acceleration rate Limit ft/s2 0.00 – 7.99 3.00 3.0
DECEL RATE 2 Deceleration Rate limit ft/s2 0.00 – 7.99 3.00 3.0
ACCEL JERK IN 2 Rate of increase in acceleration up to ACCEL
RATE when increasing elevator speed
ft/s3 0.0 – 29.9 8.0 8.0
ACCEL JERK OUT 2 Rate of decrease in acceleration to zero when
approaching contract elevator speed.
ft/s3 0.0 – 29.9 8.0 8.0
DECEL JERK IN 2 Rate of increase in deceleration to DECEL
RATE when decreasing elevator speed
ft/s3 0.0 – 29.9 8.0 8.0
DECEL JERK OUT 2 Rate of decrease in deceleration to zero when
slowing the elevator to leveling speed.
ft/s3 0.0 – 29.9 8.0 8.0
ACCEL RATE 3 Acceleration rate Limit ft/s2 0.00 – 7.99 3.00 3.0
DECEL RATE 3 Deceleration Rate limit ft/s2 0.00 – 7.99 3.00 3.0
ACCEL JERK IN 3 Rate of increase in acceleration up to ACCEL
RATE when increasing elevator speed
ft/s3 0.0 – 29.9 8.0 8.0
ACCEL JERK OUT 3 Rate of decrease in acceleration to zero when
approaching contract elevator speed.
ft/s3 0.0 – 29.9 8.0 8.0
DECEL JERK IN 3 Rate of increase in deceleration to DECEL
RATE when decreasing elevator speed
ft/s3 0.0 – 29.9 8.0 8.0
DECEL JERK OUT 3 Rate of decrease in deceleration to zero when
slowing the elevator to leveling speed.
ft/s3 0.0 – 29.9 8.0 8.0
Table 10. Quattro PM Elevator Drive, iControl