8.3SiteControllerFailureImpactonGTR8000BaseRadioforTrunkedOperation
Table8-3LocalPasswordandSNMPv3PassphraseTroubleshooting
Scenario
SNMPv3
Passphrase
Known
Local
Password
Known
ToResetSNMPv3
Passphrase
ToResetLocalLogin
Password
Userislockedoutof
locallogin,butknows
SNMPv3passphrases
SeetheCSSOnline
Help's“SNMPv3User
Conguration”.
SeetheCSSOnline
Help's“ResettingDevice
Passwords.”
Userknowslocal
login,butnotthe
SNMPv3passphrases
SeetheCSSOnline
Help's“ResetSNMPv3
Conguration(Serial)”.
SeetheCSSOnline
Help's“DeviceSecurity
CongurationSecurity
Services(Serial)”
Userknowsboth
passphrasesandlocal
servicepassword
SeetheCSSOnline
Help's“SNMPv3User
Conguration”.
SeetheCSSOnline
Help's“DeviceSecurity
CongurationSecurity
Services(Serial)”
Userdoesnotknow
SNMPv3passphrase
norserviceaccount
password
ContactMotorola
SolutionsCustomer
Support.
ContactMotorola
SolutionsCustomer
Support.
8.3SiteControllerFailureImpactonGTR8000Base
RadioforTrunkedOperation
Ifthelinkfailsbetweenthebaseradioandthesitecontroller,thebaseradiodekeysanddoesnothandleany
MSUtrafc.MSUsattempttooperateonanotherchannelatthesite.Ifanotherchannelisnotavailable,the
MSUsattempttoregisteratanothersite.
ForHPDoperation,thebaseradioreceivesexternalfrequencyreferenceandnetworktimesynchronizationfromthe
activesitecontrollerovertheEthernetlink.Intheeventoflossoftheexternaltimeandfrequencyreferencesource,
thebaseradiocontinuestomaintainitsowntimeandfrequencystabilitytocontinueoperationsforaspecied
amountoftimewithoutdegradation.Afteraperiodoftime,operationcontinueswithminimaldegradation.
8.4ConventionalSiteControllerFailure-Impacton
GTR8000forConventionalOperation
ForIPinterfacedconventionalbaseradios,aconventionalsitecontrollerprovidessupportfordispatchconsolesto
manageandcontroltheconventionalbaseradiosinK1/K2andM1/M2/M3typesystems,theconventionalsite
controlleronlyprovidessupportfortheconsoletomanageandcontroltheconventionalbaseradioswhenthe
primary(andoptionalsecondary)zonecontrollersarenotreachable.
Iftheconventionalsitecontrollerfailswhenitistheactivecallcontrollerineithertypesystem,thedispatchconsole
losesitsabilitytomanageandcontrolthechannelresources.However,subscriberradiosmaystillbeableto
maintaincommunicationsusingrepeatfunctionalityofthebaseradiosorwhenthebaseradiosareconnectedtoa
comparator.Thecomparatorsrepeatfunctionalityenableswidearearepeatforsubscribers.
6871022P86-A-November20128-7