CHAPTER 3 SYSTEM DATA PROGRAMMING
– 101 – NWA-008853-001 Rev.3.0
97ch3001.fm
DESCRIPTION DATA
When using the programmable PAD (CM35
Y=19, 2nd Data=0-3), assign the PAD data for
the DTI/CCT.
(1)
(2)
50-65: See tables below.
00-15: See tables below.
D
CM42
[Australia/New Zealand]
T/R: Transmit/Receive
+: Gain
–: Loss
PAD DATA PATTERNS
CONNECTING
PATTERNS (A-B)
CM35 Y=19
2ND DATA=0
CM35 Y=19
2ND DATA=1
CM35 Y=19
2ND DATA=2
CM35 Y=19
2ND DATA=3
50
65
50 54 58 62 STA/TONE-DTI/CCT
51 55 59 63 COT/DID/LDT/IPT-DTI/
CCT
52 56 60 64 ODT (4W E&M)-DTI/CCT
53 57 61 65 DTI/BRT/PRT/CCT/Virtual
IPT/CFTC-DTI/CCT
PATTERNS
2ND DATA
PAD DATA OF
B TRUNK
DTI /CCT
(T/R) [dB]
00
15
00 0/0
01 –3/–3
02 –8/–8
03 –6/–6
04 0/0
05 0/–6
06 –6/0
07 0/0
08
15
Not Used
PATTERNS
1ST DATA
~
~
~
E
DIGITAL CCIS PROGRAMMING