CHAPTER 3 SYSTEM DATA PROGRAMMING
– 209 – NWA-008853-001 Rev.3.0
97ch3003.fm
DESCRIPTION DATA
Assign the data as follows.
1st Data 2nd Data
CCIS channel No. 0
(0-7) for
Center Office
See Example 3: Data Assignment of CMA7
Y=03, 04. Page 227
•
(1)
(2)
Y=03
0-7: CCIS channel No.
0 : Distant end is Center Office
1 : Distant end is Local Office
Assign Centralized Billing destination.
See Example 3: Data Assignment of CMA7
Y=03, 04. Page 227
•
(1)
(2)
Y=04
0-7: CCIS channel No.
00001-16367: Point Code of Center Office.
Assign Originating Office number for Open
Numbering Plan.
See Example 4: Data Assignment of CMA7
Y=06 and CMD004>55 Page 228
•
(1)
(2)
Y=06
0-7: CCIS channel No.
0-9999: Originating Office No.
Assign the billing office number, if required. •
(1)
(2)
Y=07
0-7: CCIS channel No.
0-9999: Billing Office No.
Specify the SMDR Message Format of billing
information for Built-in SMDR.
[Series 3400 software required]
•
(1)
(2)
Y=01
07
00 : Extended NEAX 2400 IMS Format
15 : Former NEAX 2400 IMS Format
A
CMA7
CM04
END