CHAPTER 3 SYSTEM DATA PROGRAMMING
– 254 – NWA-008853-001 Rev.3.0
97ch3004.fm
NOTE: When a fault occurs, the external alarm kind registered in the 2000 IPS in the CCIS network is
displayed on Centralized MAT on the 2400 IPX office as follows:
DFTD 99/08/30 14:57 xxxxxxxxxxxxxxx
SYSTEM MESSAGE 15-0 IVS MESSAGE
xxxxxxxxx Aug 30 14:56
LP00-0-ACT
DFTD 99/08/30 14:57 XXXXXXXXX : Date of external alarm message output
SYSTEM MESSAGE 15-0 IVS MESSAGE : Means that the fault information is transferred from the
2000 IPS.
1: 3F EE 01 00 00 00 00 00
3F EE : Point Code of a 2000 IPS which external alarm message
outputs
01 : External alarm kind of fault information at the 2000 IPS
01: MJ alarm
02: MN alarm
04: --alarm
00 : Summary information (00 fixed)
For details, refer to the manuals for the 2400 IPX.
1: 3F EE 01 00 00 00 00 00 2:00 00 00 00 00 00 00 00 3:00 00 00 00 00 00 00 00
4: 00 00 00 00 00 00 00 00
5: 00 00 00 00 00 00 00 00 6:00 00 00 00 00 00 00 00 7:00 00 00 00 00 00 00 00
8: 00 00 00 00 00 00 00 00
CENTRALIZED MAT-CCIS