CHAPTER 3 SYSTEM DATA PROGRAMMING
– 267 – NWA-008853-001 Rev.3.0
97ch3004.fm
Operating Procedure
The outside calling party dials the telephone number, as usual. The call is answered at a predetermined
station, within the CCIS network, by passing the Attendant Console.
DESCRIPTION DATA
Assign Trunk Route data to the trunk route
number (for OG route).
(1)
(2)
Y=04
Answer Signal from Distant Office
00-63: Trunk Route No.
2: Arrive
(1)
(2)
Y=05
Release Signal from Distant Office
00-63: Trunk Route No.
1 : Arrive
Specify the combination of trunk routes allow-
ing the Tandem connection.
(1)
(2)
Y=00
XX ZZ
XX: 00-63 (Incoming Trunk Route)
ZZ : 00-63 (Outgoing Trunk Route for
CCIS)
0: Allow
Assign the System Speed Dialing memory area
used exclusively for DIT-Outside.
(1)
(2)
66: Exclusive for DIT-Outside
XXX YYY
XXX: 000-299 (Starting Memory Slot No.
in Block)
YYY: 001-300 (No. of Slots to be
assigned in Block)
NONE : No data
Set the stored number to the Memory Slot
number allocated by CM71.
(1)
(2)
Y=0
000-299: Memory Slot No.
XXXX YY...Y
XXXX : Access Code (Maximum 4 digits)
: Separator Mark
YY...Y : Calling Party’s No.
(Maximum 26 digits)
When no release signal arrives on the IC trunk,
specify the timer for forced disconnection
when the called party does not answer.
(1)
(2)
Y=0
55
01-13: 8-60 seconds (4 second increments)
If no data is set, the default setting is 20-24
seconds.
A
CM35
CM36
CM71
CM72
,
,
CM41
END
JANUARY/31/2006