CHAPTER 3 SYSTEM DATA PROGRAMMING
– 323 – NWA-008853-001 Rev.3.0
97ch3005.fm
For the Satellite Office
Use the LDN Diversion feature.
DESCRIPTION DATA
Assign a Trunk Restriction Class to each sta-
tion.
(1)
(2)
Y=01
X-XXXXXXXX: Station No.
XZ
Z: 1-8: Trunk Restriction Class in Night
Mode
1: Unrestricted (RCA)
2: Non-Restricted 1 (RCB)
3: Non-Restricted 2 (RCC)
4: Semi-Restricted 1 (RCD)
5: Semi-Restricted 2 (RCE)
6: Restricted 1 (RCF)
7: Restricted 2 (RCG)
8: Fully-Restricted (RCH)
Assign Service Restriction Class B to the re-
quired stations.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
ZZ: 00-15 : Service Restriction Class B
Allow Trunk Answer From Any Station in Ser-
vice Restriction Class B assigned by CM12
Y=02.
(1)
(2)
Y=53
00-15: Service Restriction Class B as-
signed by CM12 Y=02
1 : Allow
Provide the system with the Diversion Display
and the LDN Diversion features.
(1)
(2)
204: Diversion Display
0: To provide
(1)
(2)
205: LDN Diversion
0: To provide
Assign the indialed number to each TIE key on
the ATTCON. But, the ATTCON should not be
equipped in the Satellite Office. The indialed
number should be different from any numbers
assigned by CM10/CM14 and CM11.
(1)
(2)
Y=02
1-8: TIE key No.
X-XXXX: Indialed No.
START
CM12
CM15
CM08
CM50
A
TRUNK ANSWER FROM ANY STATION-CCIS