CHAPTER 3 SYSTEM DATA PROGRAMMING
– 324 – NWA-008853-001 Rev.3.0
97ch3005.fm
DESCRIPTION DATA
Assign the data for LDN Diversion to each in-
dialed number assigned by CM50 Y=02.
(1)
(2)
Y=00 Tenant No. of the LDN
01-08: TIE 0-7 assigned by CM50 Y=02
00-63: Tenant No.
(1)
(2)
Y=01 TAS Group No.
Same as CM58 Y=00
00-63: TAS Group No.
(1)
(2)
Y=02 Day Mode Destination
Same as CM58 Y=00
08: To TAS
(1)
(2)
Y=03 Night Mode Destination
Same as CM58 Y=00
08: To TAS
Specify the function of each type of TAS with-
in a system.
(1)
(2)
Y=0-4 TAS Answer A-E
1: Tie Line/Dial-in
0 : Cannot be answered
1 : Can be answered
(1)
(2)
7: A call terminated to a different tenant
0 : Can be answered
1 : Cannot be answered
Assign the access code for each type of TAS
(TAS Answer A-E) assigned by CM53.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A047: TAS Answer A
A048: TAS Answer B
A049: TAS Answer C
A050: TAS Answer D
A051: TAS Answer E
A
CM58
CM53
(1)
Y
17
0
TAS
Answer A
0/1 0/1
1
TAS
Answer B
0/1 0/1
2
TAS
Answer C
0/1 0/1
3
TAS
Answer D
0/1 0/1
4
TAS
Answer E
0/1 0/1
CM20
B
TRUNK ANSWER FROM ANY STATION-CCIS