CHAPTER 3 SYSTEM DATA PROGRAMMING
ā 328 ā NWA-008853-001 Rev.3.0
97ch3005.fm
To provide the telephone set for TAS Indication:
DESCRIPTION DATA
Assign the TAS Buzzer number (Telephone set
for TAS Indication) to the required LEN. The
TAS Buzzer number must correspond with the
TAS Group number assigned by CM30 Y=17.
E600-E663 TAS Group 00-63
NOTE: We recommend the setting of TAS
Buzzer number by CM14, when us-
ing Series 3200 R6.2 software or
later.
(1)
(2)
000-763: LEN
E600-E663: TAS Buzzer No.
Assign the TAS Buzzer number (Telephone set
for TAS Indication) to the required LEN. The
TAS Buzzer number must correspond with the
TAS Group number assigned by CM30 Y=17.
E600-E663 TAS Group 00-63
[Series 3200 R6.2 software required]
(1)
(2)
XX ZZZ (LEN)
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
E600-E663: TAS Buzzer No.
NONE : No data
START
CM10
CM14
END
TRUNK ANSWER FROM ANY STATION-CCIS