CHAPTER 3 SYSTEM DATA PROGRAMMING
– 346 – NWA-008853-001 Rev.3.0
97ch3005.fm
For a VMS office (Office B)
DESCRIPTION DATA
Provide Voice Mail Live Record-CCIS.
NOTE: Set the second data to “0” for all the
VMS ports performing Voice Mail
Live Record-CCIS.
(1)
(2)
Y=57
X-XXXXXXXX: Voice mail station No.
0: To provide
Specify whether a Live Record Start signal that
includes caller information (such as station
number and a kind of calling party) is sent to
the VMS.
(1)
(2)
702
0: To send
Specify whether a release signal is sent to the
VMS, when a station/trunk hangs up while ac-
cessing the VMS
(1)
(2)
704
0: To send
Specify whether MW lamp control on a station
of an opposite office from the VMS via CCIS
is available.
NOTE: 1st data=0 is effective only when
CM08>702: 0.
(1)
(2)
706
0 : Available
1 : Not available
START
CM13
CM08
END