NEC SL1100 Issue 6.0
Networking Manual 7 - 25
6.8 SIP Protocol
10-23-02
SIP System Interconnection
Setup – IP Address
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
Default is 0.0.0.0
Define the IP address of
another system.
10-23-04
SIP System Interconnection
Setup – Dial Number
Up to 12 digits (0 ~ 9)
Default not assigned
Determine another system call
control port number.
Program/Item
No.
Description/
Selection
Assigned Data Comments
Program/Item
No.
Description/
Selection
Assigned Data Comments
84-14-06
SIP Trunk Basic Information
Setup – SIP Trunk Port
Number
1 ~ 65535
Default is 5060 = Profile 1
5062 = Profile 2
Version 5.0 or higher: Select SIP
Profile 1-2.
Set the SIP UA (User
Authorized) Trunk port number
(Receiving Transport for NEC
SL1100 SIP).
84-14-07
SIP Trunk Basic Information
Setup – Session Timer
Value
0 ~ 65535 seconds
Default is 0
Version 5.0 or higher: Select SIP
Profile 1-2.
Set the Session Timer Value.
0 means session timer is Off
84-14-08
SIP Trunk Basic Information
Setup – Minimum Session
Timer Value
0 ~ 65535 seconds
Default is 1800
Version 5.0 or higher: Select SIP
Profile 1-2.
Set the Minimum Session Timer
Value.