NEC SL1100 Issue 6.0
Networking Manual 13 - 15
10-19-01 VoIPDB DSP Resource
Selection
This program is used to assign
the 16 or 32 resources of the
VoIPDB.
NEC recommends leaving the
default settings as system
default.
.
0 = Commonly used for IP extensions,
trunks, and networking
1 = Use for IP extensions
2 = Use for SIP trunks
3 = Use for networking (SL Net)
5 = Blocked
6 = Common without unicast paging
7 = Multicast paging
8 = Unicast paging
(defaults: resource1 = Use for IP extensions,
resource 2 ~ 32 = Common)
10-20-01 External Equipment LAN setup
Device type 4 (networking
system) must be assigned to
the same port number in ALL
SL Net systems.
1 = CTI Server (default = 8181)
2 = ACD MIS (default = 4000)
4 = Networking System (default = 30000)
5 = SMDR Output (default = 0)
6 = DIM Output (default = 0)
9 = 1st Party CTI (default = 8282)
11 = O&M Server (default = 8010)
12 = Traffic Report Output (default = 0)
13 = Room Data Output for Hotel Service
(default = 0)
14 = IP-DECT Directory Access (default = 0)
Available values are: 0 ~ 65535
90-10-01 System Alarm Setup
Two Alarms were added for SL
Net and they are:
Alarm 15 – Networking keep
alive error
Alarm 59 – Networking port limit
exceeded
0 = No Setting
1 = Major Alarm
2 = Minor Alarm
(Refer to the SL1100 programming manual
for the default values.)
90-10-02 Report
This program is used to assign if
the alarm is displayed on a key
telephone if the alarm
information is reported to the
pre-defined destination.
0 = No (alarm disabled)
1 = Yes (alarm enabled)
(Refer to the SL1100 programming manual
for the default values.)
Program
Number
Program Name/Description Assigned Data