45584901TH Rev.1
11-89 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
Mode
System General Real time log
notification function
3626 Department
information
transmission setting
0 0-1 SYS Setswhetherthedepartmentinformation(number,
name,code)istransmittedornotintherealtimelog
notification function.
0:Departmentnumber,departmentname,department
code
1:Departmentnumber,departmentname
1
08 Setting
mode
System General 3629 Enable/Disable
setting of standard
EWBfunction
1 0-1 SYS 0: Disabled
1: Enabled
*ThiscodeisvalidforODA(ODC-IT),ODA(ODC-OA),
OEL(ODC-IT),andOEL(ODC-OA).
1
08 Setting
Mode
System Network 3631 Remote Access
(SNMP)
1 0-1 SYS 0: Disabled
1: Enabled
1
08 Setting
mode
System User
interface
3635 Trial copy function 1 0-1 SYS 0: Disabled
1: Enabled
1
08 Setting
mode
System Network 3702 LogonUserName
ofWindowsDomain
Authentication
MFP's
serial
number
- - Maximum 128 letters
“MFP'sserialnumber”issetasdefault.Perform08-9083
to set the default value.
12
08 Setting
mode
System Network 3703 LogonUserName
Password of
WindowsDomain
Authentication
- - NIC Maximum 128 letters 12
08 Setting
mode
System Network 3704 PDC2 of user
authentication
- - UTY Maximum 128 letters 12
08 Setting
mode
System Network 3705 BDC2 of user
authentication
- - UTY Maximum 128 letters 12
08 Setting
mode
System Network 3706 PDC3 of user
authentication
- - UTY Maximum 128 letters 12
08 Setting
mode
System Network 3707 BDC3 of user
authentication
- - UTY Maximum 128 letters 12
08 Setting
mode
System Network 3708 PDCofWindows
Domain
Authentication
- - NIC Maximum 128 letters 12
08 Setting
mode
System Network 3709 BDC of device
authentication
- - NIC Maximum 128 letters 12
08 Setting
mode
System Network 3718 Domain name of
WindowsDomain
Authentication
- - NIC Maximum 128 letters 12
08 Setting
mode
System Network 3719 Windowsdomain
No.2 of user
authentication
- - UTY Maximum 128 letters 12

Table of Contents

Other manuals for Oki MC770

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oki MC770 and is the answer not in the manual?

Oki MC770 Specifications

General IconGeneral
BrandOki
ModelMC770
CategoryAll in One Printer
LanguageEnglish

Related product manuals