4.3.19 Auto Trapping width/density adjustment (PS)
<Adjustment Mode (05)>
Code Item to be adjusted Remarks
8244-0 Trapping width (dot) Setsthevalueofwidthforautotrapping.Whenthevalue
increases,thebiggergapissuppressed,buttheoverlap
part becomes more visible.
1: 1 dot
2: 2 dot
3: 3 dot (default)
8214 Trapping density (%) Setsthevalueofdensityforautotrapping.Whenthevalue
increases,thebiggergapissuppressed,buttheoverlap
part becomes more visible.
0: 100% (default)
1: 75%
2: 50%
3: 25%
<Procedure>
The procedure is the same as that of
P.4-13“4.3.4Adjustmentoffainttext”.