EasyManuals Logo

Omron F3SJ Series User Manual

Omron F3SJ Series
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
81
F3SJ-A
User’s Manual
Chapter3 Setting Adjusted to Application
What can be done by the setting tool
E
3. Position Detection Muting Mode
Muting Zone Setting
Setting tool provides designation of beams for muting. (All beams are specified for factory shipment)
You can specify a beam by teaching, with which the sensor learns muting beams as those interrupted,
or manually.
Muting Zone Setting Example
•Setting from F3SJ’s upper beams (figure 1)
•Setting multiple zones (figure 2)
- Only one zone can be configured as a muting zone by the setting console, which cannot set more than one zone.
- Interlock function is disabled for a muting system.
If you want to use start or restart interlock, use the setting tool to enable the function.
Interlock Function p.99
- When muting function is enabled, a muting lamp is turned on to notify people in the surrounding zone that the safety
functions are disabled. Factory setup is external indicator outputs 1 and 2.
While the setting tool allows change of output destination for a muting lamp, muting/override information must be set
to at least one of auxiliary output 1 or external indicator outputs 1 or 2.
If none of the above output is set, F3SJ enters lockout.
- Auxiliary output 1, external indicator outputs 1 and 2 have diagnosis function.
For safety reason, using diagnosis function is recommended.
- Auxiliary Output (Non-Safety Output) p.94
- External Indicator Output (Non-Safety Output) p.98
1. Standard Muting Mode
Operation mode configured for F3SJ factory shipment.
Turning muting inputs 1 and 2 ON with time difference enables muting function.
For details, see Muting in Chapter 2.
Muting System p.35
Setting can be changed, such as muting time limit.
2. Exit Only Muting Mode (Setting is Available Only for PC Tool For F3SJ)
Turning muting inputs 1 and 2 ON with time difference enables muting function.
Difference from standard mode exists in muting completion condition.
Lower
Upper
Lower
Upper
Muting zone
Muting zone
Muting zone
Normal detecting beam
Muting beams
Figure 1
Figure 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SJ Series and is the answer not in the manual?

Omron F3SJ Series Specifications

General IconGeneral
TypeSafety Light Curtain
Safety CategoryCategory 4
Protection RatingIP67
SILSIL3
Operating Temperature-10°C to +55°C
Detection MethodInfrared
Resolution14 mm
IP RatingIP67
CertificationCE
Power Supply Voltage24 VDC ±10%