106
Chapter3 Maintenance Information
F3SJ-A
User’s Manual
What can be done by the setting tool
• Accumulated power-on time
This value represents the cumulative power-on time, from the time that the power was first supplied
until the present. It is not possible to reset this value using the power-on time reset function.
• Power-on time reset
This function can reset the power-on time of the F3SJ to 0. In the case of series connection, the
power-on time can be reset for each F3SJ CH.
Monitor Items
Configure or display for each CH in case of a series connection.
Function Initial Setting Available Setup Item Setting Console PC Tool For F3SJ
Power-on time Read out only
Power-on time threshold value 30,000 hours Setting Console:
100 to 999,900 hours (by 100 hours)
PC Tool for F3SJ:
100 to 1,000,000 hours (by 100 hours)
Accumulated power-on time Read out only
Power-on time reset – Reset