5 Basic Settings
5 - 9
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Application
Adjustment method
Motor integrated with a brake (that uses
a shared power supply for the motor and
the brake)
If the motor and the brake share the same power supply, a large volt-
age is required at low frequencies to release the brake.
The release timing of the brake can be adjusted by setting the fre-
quency at which you want to release the brake and adjusting the volt-
age at that frequency.
Applications subject to significant load
variation at different motor speeds
When the load value changes significantly depending on the motor
speed, the output torque of the inverter can be adjusted by setting the
frequency at which the load value becomes large and adjusting the
voltage at that frequency.
Reduced Torque Characteristics (VP 1.7th Power (VC at low speed))
5
5-2 V/f Control Settings
5-2-1 Control Method (V/f Characteristics)
Free V/f Function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC