EasyManuals Logo

Omron MX2 Series User Manual

Omron MX2 Series
612 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
1 Overview
1 - 13
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Item
3-phase 400 V
Model
(3G3MX2--EV2)
A4004
A4007
A4015
A4022
A4030
A4040
A4055
A4075
A4110
A4150
Maximum
applicable
motor
capacity
*1
kW
CT
0.4
0.75
1.5
2.2
3.0
4.0
5.5
7.5
11
15
VT
0.75
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5
HP
CT
1/2
1
2
3
4
5
7 1/2
10
15
20
VT
1
2
3
4
5
7 1/2
10
15
20
25
Rated out-
put capac-
ity [kVA]
380 V
CT
1.1
2.2
3.1
3.6
4.7
6.0
9.7
11.8
15.7
20.4
VT
1.3
2.6
3.5
4.5
5.7
7.3
11.5
15.1
20.4
25.0
480 V
CT
1.4
2.8
3.9
4.5
5.9
7.6
12.3
14.9
19.9
25.7
VT
1.7
3.4
4.4
5.7
7.3
9.2
14.5
19.1
25.7
31.5
Rated input voltage
3-phase 380 V 15% to 480 V +10%, 50/60 Hz ±5%
Rated input current
[A]
CT
1.8
3.6
5.2
6.5
7.7
11.0
16.9
18.8
29.4
35.9
VT
2.1
4.3
5.9
8.1
9.4
13.3
20.0
24.0
38.0
44.0
Rated output voltage
*2
3-phase 380 to 480 V (Less than incoming voltage)
Rated output current
[A]
CT
1.8
3.4
4.8
5.5
7.2
9.2
14.8
18.0
24.0
31.0
VT
2.1
4.1
5.4
6.9
8.8
11.1
17.5
23.0
31.0
38.0
Braking torque during
short-time deceleration
[%]
*3
(discharge resistor not
connected)
50
50
50
20
20
20
20
20
10
10
Braking
resistor
circuit
*4
Regenera-
tive braking
Built-in braking resistor circuit (discharge resistor separately mounted)
Minimum
connection
resistance
[]
180
180
180
100
100
100
70
70
70
35
Cooling method
Self-cooling
(without fan)
Forced air cooling (with fan)
Weight [kg]
1.5
1.8
1.8
1.8
2.0
2.0
3.5
3.5
4.5
4.5
Dimensions (Width
Height) [mm]
108 128
140
128
140 260
180 296
Dimensions (Depth)
[mm]
146.5
173.5
158
168
3-phase 400-V Class
1
1-3 Specifications
1-3-1 Standard Specifications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC

Related product manuals