8 Communications Functions
8 - 52
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
1203
hex
1202 hex
1st Base Frequency
A003
R/W
300 to 1st Maximum Fre-
quency
0.1 [Hz]
P. 5-20
1204
hex
1203 hex
1st Maximum
Frequency
A004
R/W
1st Base Frequency to
5900
0.1 [Hz]
P. 5-20
1205
hex
1204 hex
O/OI Selection
A005
R/W
00: Switch between O
and OI
02: Switch between O
and volume
03: Switch between OI
and volume
P. 7-22
1206 to
120A
hex
Reserved
120B
hex
120A hex
O Start Frequency
A011
(HIGH)
R/W
0 to 59000
0.01
[Hz]
*1
P. 7-25
120C
hex
120B hex
A011
(LOW)
120D
hex
120C hex
O End Frequency
A012
(HIGH)
R/W
0 to 59000
0.01
[Hz]
*1
120E
hex
120D hex
A012
(LOW)
120F
hex
120E hex
O Start Ratio
A013
R/W
0 to 100
1 [%]
1210
hex
120F hex
O End Ratio
A014
R/W
0 to 100
1 [%]
1211
hex
1210 hex
O Start Selection
A015
R/W
00: O Start Frequency
(A011)
01: 0 Hz
1212
hex
1211 hex
Analog Input Filter
A016
R/W
1 to 30/31 (500-ms filter
with ±0.1-Hz hysteresis)
1
P. 7-24
1213
hex
1212 hex
DriveProgramming
Function Selection
A017
R/W
00: Disabled
01: Enabled (Start/stop
via multi-function
input PRG terminal)
02: Enabled (Start/stop
at power on/off)
1214
hex
Reserved
1215
hex
1214 hex
Multi-step Speed
Selection
A019
R/W
00:
Binary (16-step selec-
tion with 4 terminals)
01:
Bit
(8-step
selection
with 7 terminals)
P. 5-28
1216
hex
1215 hex
1st Multi-step Speed
Reference 0
A020
(HIGH)
R/W
0
Starting Frequency to 1st
Maximum Frequency
0.01
[Hz]
*1
1217
hex
1216 hex
A020
(LOW)
R/W
1218
hex
1217 hex
Multi-step Speed
Reference 1
A021
(HIGH)
R/W
0
Starting frequency to
Maximum frequency
0.01
[Hz]
*1
1219
hex
1218 hex
A021
(LOW)
R/W
121A
hex
1219 hex
Multi-step Speed
Reference 2
A022
(HIGH)
R/W
0
Starting frequency to
Maximum frequency
0.01
[Hz]
*1
121B
hex
121A hex
A022
(LOW)
R/W

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC