8 Communications Functions
8 - 79
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
146A
hex
1469 hex
Reset Selection
C102
R/W
00: Trip reset at
power-on
01: Trip reset at
power-off
02: Enabled only
during trip (Reset
at power-on)
03: Trip reset only
P. 5-42
146B
hex
146A hex
Reset Restart
Selection
C103
R/W
00: 0 Hz restart
01: Frequency pull-in
restart at shutoff
02: Frequency pull-in
restart
146C
hex
146B hex
UP/DWN Clear
Selection
C104
R/W
00: 0 Hz
01: EEPROM data at
power-on
P. 7-40
146D
hex
146C hex
EO Gain Setting
C105
R/W
50 to 200
1 [%]
P. 7-28
146E
hex
146D hex
AM Gain Setting
C106
R/W
50 to 200
1 [%]
P. 7-30
146F to
1470
hex
Reserved
1471
hex
1470 hex
AM Bias Setting
C109
R/W
0 to 100
1 [%]
P. 7-30
1472
hex
Reserved
1473
hex
1472 hex
1st Overload
Warning Level 2
C111
R/W
0 to 2000
0.1 [%]
P. 7-78
1474
to
1478
hex
Reserved
1479
hex
1478 hex
Jog Sensitivity
Setting
C117
R/W
1 to 24
P. 7-61
147A
hex
1479 hex
Jog Carry Sensitivity
Setting
C118
R/W
1 to 100
147B to
1485
hex
Reserved
1486
hex
1485 hex
Multi-function Output
11 ON Delay Time
C130
R/W
0 to 1000
0.1 [s]
P. 5-55
1487
hex
1486 hex
Multi-function Output
11 OFF Delay Time
C131
R/W
0 to 1000
0.1 [s]
1488
hex
1487 hex
Multi-function Output
12 ON Delay Time
C132
R/W
0 to 1000
0.1 [s]
1489
hex
1488 hex
Multi-function Output
12 OFF Delay Time
C133
R/W
0 to 1000
0.1 [s]
148A to
148F
hex
Reserved
1490
hex
148F hex
Multi-function Relay
Output ON Delay
Time
C140
R/W
0 to 1000
0.1 [s]
P. 5-55
1491
hex
1490 hex
Multi-function Relay
Output OFF Delay
Time
C141
R/W
0 to 1000
0.1 [s]
8
8-9 Modbus Communication Data Lists
8-9-4 Group A/b/C/H/P Register List