8 Communications Functions
8 - 83
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
1573
hex
1572 hex
PM Motor Pole
Number
H104
R/W
00: 2P
01: 4P
02: 6P
03: 8P
04 to 23: Do not set 10
to 48P.
P. 6-62
1574
hex
1573 hex
PM Motor Rated
Current
H105
R/W
0 to 1000
0.1 [%]
1575
hex
1574 hex
PM Motor
Parameter R
H106
R/W
1 to 65535
0.001
[]
1576
hex
1575 hex
PM Motor
Parameter Ld
H107
R/W
1 to 65535
0.01
[mH]
1577
hex
1576 hex
PM motor
Parameter Lq
H108
R/W
1 to 65535
0.01
[mH]
1578
hex
1577 hex
PM motor
Parameter Ke
H109
R/W
1 to 65535
0.0001
[Vp/
(rad/s)]
1579
hex
1578 hex
PM motor
Parameter J
H110
(HIGH)
R/W
1 to 9999000
0.001
[kgm
2
]
157A
hex
1579 hex
H110
(LOW)
157B
hex
157A hex
PM Motor
Parameter R
(Auto-tuning Data)
H111
R/W
1 to 65535
0.001
[]
P. 6-59
157C
hex
157B hex
PM Motor
Parameter Ld
(Auto-tuning Data)
H112
R/W
1 to 65535
0.01
[mH]
157D
hex
157C hex
PM Motor
Parameter Lq
(Auto-tuning Data)
H113
R/W
1 to 65535
0.01
[mH]
157E to
1580
hex
Not used
Not accessible
1581
hex
1580 hex
PM Motor Speed
Response
H116
R/W
1 to 1000
1 [%]
P. 6-64
1582
hex
1581 hex
PM Motor Starting
Current
H117
R/W
2000 to 10000
0.01
[%]
1583
hex
1582 hex
PM Motor Starting
Time
H118
R/W
1 to 6000
0.01 [s]
1584
hex
1583 hex
(Reserved)
H119
*1
R/W
0 to 120
1 [%]
1585
hex
Not used
Not accessible
1586
hex
1585 hex
PM Motor Minimum
Frequency
H121
R/W
0 to 255
0.1 [%]
P. 6-64
1587
hex
1586 hex
PM Motor No-Load
Current
H122
R/W
0 to 10000
0.01
[%]
1588
hex
1587 hex
PM Motor Starting
Method Selection
H123
R/W
00: Disabled
01: Initial pole position
estimation enabled
1589
hex
Not used
Not accessible
8
8-9 Modbus Communication Data Lists
8-9-4 Group A/b/C/H/P Register List

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC