Chapter-8
Read Options
L-46X User's Manual
103
1st
Read Time Adjustment
8.3.4
The time to end the auto trigger scanning can be adjusted.
Item
Command
Description
Default
Auto trigger read time
adjustment
[EFH
Long time
[EFI
Normal
[EFJ
Short time
*When the read time is fixed, please see: “Read Time”
Auto Trigger Sleep Mode 8.3.5
When nothing is detected after a specific configurable period while in auto trigger mode, the scanner
goes into sleep mode. The scanner performs presence detection at specified time intervals in sleep
mode and when a target is detected or any event such as trigger occurs, the unit exits from sleep
mode. Setting a time of 0 seconds means that sleep mode is disabled.
Item
Command
Description
Default
(valid range)
Auto trigger
sleep mode
[EBW
Qa
Qb
Qc
Qd
Transition time to sleep mode
(1000a+100b+10c+d) [s]
60 s
(0-9999)
Detection Mode 8.3.6
There are three methods for detecting a target code.
Warm white illumination detection
When a target code falls within the range of the field of view of the warm white light, the target is
detected. This mode is preferred in a dark environment.
Green aiming detection
When a target code falls within the green aiming light, the target is detected. This mode is
recommended for indoor use only because target detection is reduced in environments with higher
illumination levels than typically found indoors.
No illumination detection
A target code is detected without illumination light. The power consumption will be reduced, but the
effectiveness of detection will also be reduced. Ambient light is used for detection in this mode, so
this mode should not be used in a dark environment. Best used in a well-lit area.
Item
Command
Description
Default
Auto trigger
[DDH
Warm white illumination detection
[DDG
Green aiming detection
[DDI
No illumination detection

Table of Contents