Chapter-6
Code Options
L-46X User's Manual
74
1st
Codabar option settings are as follows.
Code
Item
Command
Description
Default
Codabar
CD check
H7
Not check CD
H6
Check CD
CD
transmission
H8
Transmit Codabar CD
H9
Not transmit Codabar CD
ST/SP
transmission
F0
Not transmit Start / Stop code
F1
Start / Stop code: ABCD/TN*E
F2
Start / Stop code: abcd/tn*e
F3
Start / Stop code: ABCD/ABCD
F4
Start / Stop code: abcd/abcd
HJ
Start / Stop code:
<DC1><DC2><DC3><DC4>
/<DC1><DC2><DC3><DC4>
Space
insertion
HE
Disable space insertion
HD
Enable space insertion
ABC, CX
conversion
HA
Enable only Codabar normal mode
H4
Enable only ABC code
H5
Enable only CX code
H3
Enable Codabar / ABC and CX