Replace the Battery
b.
To dislodge the battery from the retainer, gently push the battery toward the
side of the server to release it from the retention clip.
c.
Unpack the replacement battery.
d.
Press the new battery into the battery retainer with the positive side (+)
facing the side of the server.
e.
Return the server to operation.
See “Returning the Server to Operation” on page 145.
3.
Reset the system clock.
a.
Use the Oracle ILOM clock command to set the day and time.
The following example sets the date to August 22, 2016, and the timezone to EDT.
-> set /SP/clock datetime=0812213202016 timezone=EDT
Set 'datetime' to '0812213202016'
Servicing the Battery 85