Setting parameters assigned to Remote SIP-MLT—NAT - NTP Server Port No.
Specifies the outside-facing port of the network gateway connected to the NTP server.
Value Range
1–65535
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection
Setting parameters assigned to Remote SIP-MLT—NAT - Keep Alive Packet
Type
Specifies the type of Keep Alive packets to be sent out for remote connections.
Value Range
Register, Blank UDP, None
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection
Setting parameters assigned to Remote SIP-MLT—NAT - Keep Alive Packet
Sending Interval Time (s)
Specifies the time interval between transmissions of the Keep Alive packet.
Note
This interval must be shorter than the NAT binding time of the router. The default value is appropriate
in most cases.
This setting is available only when NAT - Keep Alive Packet Type is set to "Blank UDP".
Value Range
10–60 s
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection