Maintenance Console Location
9.14 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT—Port Property
Feature Guide References
5.2.1 IP Proprietary Telephone (IP-PT)
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS or OUS for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Maintenance Console Location
9.14 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT—Port Property
Feature Guide References
5.2.1 IP Proprietary Telephone (IP-PT)
DTMF
Specifies the type of DTMF tone to be sent out.
Value Range
Inband, Outband (RFC2833)
Maintenance Console Location
9.14 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT—Port Property
Feature Guide References
5.2.1 IP Proprietary Telephone (IP-PT)
Payload Type
Specifies the payload type for DTMF tones using RFC2833. Programming this parameter is only necessary if
DTMF is set to Outband (RFC2833).
Value Range
96–127
Maintenance Console Location
9.14 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT—Port Property
PC Programming Manual 311
9.14 PBX Configuration—[1-1] Configuration—Slot—V-IPEXT—Port Property