Value Range
Low, High
Maintenance Console Location
9.24 PBX Configuration—[1-1] Configuration—Slot—Port Property - LCO Port
Reverse Detection
Selects the type of trunk call for which the reverse signal from the telephone company is detected.
Value Range
Disable: For no trunk call
Outgoing: For outgoing trunk calls only
Both Call: For both outgoing and incoming trunk calls
Maintenance Console Location
9.24 PBX Configuration—[1-1] Configuration—Slot—Port Property - LCO Port
Feature Guide References
2.5.4.5 Reverse Circuit
Caller ID Detection
Enables the PBX to detect a Caller ID signal from the analogue trunk.
Value Range
Disable, Enable
Maintenance Console Location
9.24 PBX Configuration—[1-1] Configuration—Slot—Port Property - LCO Port
PC Programming Manual References
9.23 PBX Configuration—[1-1] Configuration—Slot—Card Property - LCO type
Feature Guide References
2.19.1 Caller ID
Pause Time
Specifies the length of a pause.
Value Range
1.5 s, 2.5 s, 3.5 s, 4.5 s
368 PC Programming Manual
9.24 PBX Configuration—[1-1] Configuration—Slot—Port Property - LCO Port