Maintenance Console Location
9.24 PBX Configuration—[1-1] Configuration—Slot—Port Property - LCO Port
Feature Guide References
2.5.4.7 Pause Insertion
2.5.4.8 Host PBX Access Code (Access Code to the Telephone Company from a Host PBX)
2.5.4.9 Special Carrier Access Code
Flash Time
Specifies the length of a flash signal.
Value Range
None, 16 ´ n (n=1–255) ms
Maintenance Console Location
9.24 PBX Configuration—[1-1] Configuration—Slot—Port Property - LCO Port
Feature Guide References
2.11.7 External Feature Access (EFA)
Disconnect Time
Specifies the length of time after a trunk is disconnected, during which the PBX cannot seize the line.
Value Range
0.5 s, 1.5 s, 2.0 s, 4.0 s, 12.0 s
Maintenance Console Location
9.24 PBX Configuration—[1-1] Configuration—Slot—Port Property - LCO Port
Feature Guide References
2.11.6 Flash/Recall/Terminate