4.10 Resource Programming
SMDR Incoming / Outgoing Call Log Printout
800
4-126 System Programming
Description Used to determine which calls will produce an SMDR printout.
Selection • Outgoing calls: All (all calls) / Toll (toll calls only) /
Off (no printing)
• Incoming calls: On (all calls) / Off (no printing)
Default Outgoing calls – All; Incoming calls – On
Programming 1. Enter 800.
Display: Duration Log
2. Press NEXT to program outgoing calls.
Display: Outgoing:All
3. Keep pressing SELECT until the desired selection is
displayed.
4. Press STORE.
5. Press NEXT to program incoming calls.
Display: Incoming:On
6. Keep pressing SELECT until the desired selection is
displayed.
7. Press STORE.
8. Press END.
Conditions • It is necessary to connect a printer to the EIA (RS-232C) port provided
on the system.
• After connecting a printer, do not press the RETURN key, if provided
on the printer, in 10 seconds. Otherwise, the usage of the EIA port is
changed to system programming and printout will not occur.
• If “Toll” is selected, the system will print out all the calls starting from
the numbers stored in programs [301]–[305] “TRS Denied Code Entry
for Levels 2 through 6.”
Feature References Section 3, Features,
Station Message Detail Recording (SMDR)