Loading...
4-83
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Note
Related page
•Aparameterisdesignatedasfollows:
Pr0.00
Parameter No.Class
•ForparameterswhichNo.haveasuffixof“
*
,changedcontentswillbevalidated
whenyouturnonthecontrolpower.
•P.3-32...“InputsandoutputsonconnectorX4”
Default: [ ]
1. Details of parameter
[Class 6] Special setting
Pr6.88
Absolute multi-rotation data upper limit
Range Unit Default
Related
control mode
0 to 65534 0 P S T F
Setstheupperlimitvalueforabsolutemulti-rotationdata.
Multirotationdatawillchangeto0whenthissetvaluehasbeenexceeded.
Inversely,itwillchangetothesetvalueincaseitgoeslowerthan0.
Internalvaluewillbesetto65535incasePr0.15issetto0or2(absolutemode).
Pr6.97
Functionexpansionsetting3
Range Unit Default
Related
control mode
-2147483648 to
2147483647
0 P S T F
Setsvariousfunctioninbitunits:
function Setup value
bit0
Quadrant projection compensation function
enhancement
0:Invalid 1:valid
bit1 Deteriorationdiagnosiswarningfunction 0:Invalid 1:valid
bit2
ExpansionofAllowablemotoroperatingrange
abnormal protection
0:Invalid 1:valid
bit3-31 For manufacturer use. Please set xedto0.
*bit0istheleastsignicantbit.
Pr6.98
Functionexpansionsetting4
Range Unit Default
Related
control mode
-2147483648 to
2147483647
0 P S T F
Setsvariousfunctioninbitunits:
bit0to31:Formanufactureuse.Pleasesetxedto0
*bit0istheleastsignicantbit.