5-73
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Related parameters
Class No.
Title Function
4 44
Position compare
output pulse width
setting
Sets pulse width of position compare output
No pulse output when 0 (zero)
4 45
Position compare
output polarity
select
Polarity of position compare output can be set by bit for
each output terminal.
・
Set bits
bit0
:
SO1 or OCMP1
bit1
:
SO2 or OCMP2
bit2
:
SO3 or OCMP3
bit3
:
SO4 or OCMP4
bit4
:
SO5 bit5
:
SO6
・
Set value
0
:
Sets output photocoupler to ON for SO1 to 6, during
pulse output and to L level for OCMP 1 to 4.
1
:
Sets output photocoupler to OFF for SO1 to 6,
during pulse output and to H level for OCMP 1 to 4.
Basically to be used set to 0.
4 47 Pulse output select
Selects signal to be output from pulse output/position
compare output terminal:
Set
value
Connector pin
No.21/22
Connector pin
No.48/49
Connector pin
No.23/24
Connector pin
No.19
0 OA OB OZ CZ
1 OCMP1 OCMP2 OZ CZ
2 OA OB OCMP3 OCMP3
3 OCMP1 OCMP2 OCMP3 OCMP3
4 OA OB OZ OCMP4
5 OCMP1 OCMP2 OZ OCMP4
6 OA OB OCMP3 OCMP4
7 OCMP1 OCMP2 OCMP3 OCMP4
*OA, OB, OZ, and CZ are pulse output signals and
OCMP1, OCMP2, OCMP3, and OCMP4 are position
compare output.
4 48
Position compare
output polarity select 1
Sets position compare 1 comparison value
4 49
Position compare
output polarity select 2
Sets position compare 2 comparison value
4 50
Position compare
output polarity select 3
Sets position compare 3 comparison value
4 51
Position compare
output polarity select 4
Sets position compare 4 comparison value
4 52
Position compare
output polarity select 5
Sets position compare 5 comparison value
4 53
Position compare
output polarity select 6
Sets position compare 6 comparison value
4 54
Position compare
output polarity select 7
Sets position compare 7 comparison value
7. Applied functions
Position compare output function