C-18 Parameter Specification Tables 590 Series DC Digital Drive
Tag Mn Function Block Name Parameter Name Minimum Maximum Default Units Range Notes
486 ni DIAMETER CALC. TENSION SCALER -3.0000 3.0000 1.0000 V1 W0
487 nj DIAMETER CALC. STATIC COMP -300.00 300.00 0.00 % V0 W0
488 nk DIAMETER CALC. DYNAMIC COMP -300.00 300.00 0.00 % V0 W0
489 nl DIAMETER CALC. REWIND 0 1 1 0: DISABLED
1: ENABLED
V0 W0
491 nn SETPOINT SUM 2 STPT SUM 2 OUT 0 0.00 0.00 0.00 % V0 W4
492 no SETPOINT SUM 2 STPT SUM 2 OUT 1 0.00 0.00 0.00 % V0 W4
493 np ANALOG INPUT 2 OUTPUT 0.00 0.00 0.00 % V0 W4
494 nq LINK 37 DESTINATION TAG 0 1298 496 V0 W2
495 nr LINK 38 DESTINATION TAG 0 1298 497 V0 W2
496 ns SEQUENCING JOG/SLACK 0 1 0 0: OFF
1: ON
V0 W0
497 nt SEQUENCING ENABLE 0 1 0 0: OFF
1: ON
V0 W0
498 nu DIAMETER CALC. LINE SPEED SPT -105.00 105.00 0.00 % V0 W0
499 nv MAIN PORT (P1) OPTION ADDRESS 0 32767 0 V0 W0
525 ol SEQUENCING COAST STOP 0 1 0 V0 W4
527 on CURRENT LOOP MASTER BRIDGE 0 1 0 V0 W4
528 oo ALARMS LAST ALARM 0x0000 0xFFFF 0x0000 V0 W4
535 ov SEQUENCING REM.SEQ.ENABLE 0 1 0 V0 W1
536 ow SEQUENCING REM.SEQUENCE 0x0000 0xFFFF 0x8000 V1 W0
537 ox SEQUENCING SEQ STATUS 0x0000 0xFFFF 0x0000 V0 W4
540 p0 ALARMS REM TRIP INHIBIT 0 1 0 0: ENABLED
1: INHIBITED
V0 W0
541 p1 ALARMS REM TRIP DELAY 0.1 600.0 10.0 s V0 W0
542 p2 ALARMS REMOTE TRIP 0 1 0 V0 W4
547 p7 SPEED LOOP SPD.FBK.FILTER 0.000 1.000 0.000 V0 W0
549 p9 SPEED LOOP SPEED LOOP O/P 0.00 0.00 0.00 % V0 W4
556 pg INERTIA COMP INERTIA 0.00 200.00 0.00 V0 W0
557 ph INERTIA COMP FILTER 0 20000 0 V0 W0
558 pi INERTIA COMP RATE CAL 0.00 200.00 100.00 V0 W0
559 pj PRESET SPEEDS MAX SPEED 0.1 3000.0 100.0 % V0 W0
560 pk PRESET SPEEDS SELECT 1 0 1 0 V0 W0
561 pl PRESET SPEEDS SELECT 2 0 1 0 V0 W0
562 pm PRESET SPEEDS SELECT 3 0 1 0 V0 W0
563 pn PRESET SPEEDS INVERT O/P 0 1 0 V0 W0
564 po PRESET SPEEDS INPUT 0 -3000.0 3000.0 0.0 V0 W0
565 pp PRESET SPEEDS INPUT 1 -3000.0 3000.0 0.0 V0 W0
566 pq PRESET SPEEDS INPUT 2 -3000.0 3000.0 0.0 V0 W0
567 pr PRESET SPEEDS INPUT 3 -3000.0 3000.0 0.0 V0 W0