EasyManua.ls Logo

Parker 591C - Aux I;O

Parker 591C
401 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-28 Programming 590 Series DC Digital Drive
AUX I/O
The auxiliary I/O parameters are primarily intended to extend the functionality of the serial links by
allowing them access to the drive analog and digital terminals.
AUX I/O
Parameter Tag Range
AUX DIGOUT 1 94 FALSE / TRUE
Software digital output 1. For example, to directly drive the configurable digital output DIGOUT1, connect the Source of DIGOUT1 to this parameter,
Tag 94.
AUX DIGOUT 2 95 FALSE / TRUE
Software digital output 2. For example, to directly drive the configurable digital output DIGOUT2, connect the Source of DIGOUT2 to this parameter,
Tag 95.
AUX DIGOUT 3 96 FALSE / TRUE
Software digital output 3. For example, to directly drive the configurable digital output DIGOUT3, connect the Source of DIGOUT3 to this parameter,
Tag 96.
ANOUT 1 128 -100.00 to 100.00 %
Software analog output 1. For example, to directly drive the configurable analog output ANOUT1, connect the Source of ANOUT1 to this parameter,
Tag 128. ANOUT 1 can also be used as a general "staging post" for connecting inputs to outputs. For example, connect Analog Input 1 (A2) directly
to Analog Output 1 (A7)
ANOUT 2 129 -100.00 to 100.00 %
Software analog output 2. For example, to directly drive the configurable analog output ANOUT2, connect the Source of ANOUT2 to this parameter,
Tag 129. ANOUT 2 can also be used as a general "staging post" for connecting inputs to outputs. For example, connect Analog Input 1 (A2) directly
to Analog Output 2 (A8)