EasyManua.ls Logo

Parker 591C - Connection Diagrams

Parker 591C
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-12 Installing the Drive 590 Series DC Digital Drive
Connection Diagrams
EMERGENCY
STOP
RELAY
AUXILIARY
SUPPLY
SIGNAL 0V
SPEED SETPOINT No. 1
CURRENT DEMAND
TOTAL SETPOINT
ZERO
SPEED
DRIVE
HEALTHY
DRIVE
READY
SET
SPEED
MICROTACH
SELECT FEEDBACK TYPE
FROM MMI
RS 485 LINK
C1 C2 F1 C9 G3/G1 A+
10K
START
/
RUN
ENABLE
B9A1 B8 C5 C3
B3A4B4A8A3
A2
A6
B5 B6 B7
H4
H3
H2
H1C9
C1
H5 H6 D1 D2 D7
G4/G2
D8 D6 D5 L1 L2
D3 D4 PE A-
L3 PE
FIELD
+
THERMISTOR
TACHO
S
S
S
RL
RL
RL
ARMATURE
M
PE
AC FIELD
SUPPLY
590
CONTROLLER
**
USE INTERNAL
FIELD CONNECTION
FOR EMC COMPLIANCE
*
MAIN SERIAL PORT (P1)
PROTECTIVE
EARTH
FILTER
OPTIONAL
START
CONTACTOR
CON
3 PHASE
SUPPLY
HIGH SPEED
FUSES
STAR POINT EARTH
NEAR DRIVE
AC LINE CHOKE
SPEED SETPOINT No
. 2/
E1 – E6
+
ENCODER
Figure 3- 5 Minimum Connection Requirements (`general purpose’ configuration)
Bold lines indicate
"minimum connections"

Table of Contents