EasyManua.ls Logo

Parker 591C - Sramp

Parker 591C
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D-112 Programming 590 Series DC Digital Drive
SRAMP
This function block limits the rate of change of an input by limiting the acceleration and
the jerk (rate of change of acceleration).
SRAMP
Parameter Tag Range
INPUT 574 -100.00 to 100.00 %
Input value.
RATE SELECT 575 0 to 1
Selects between one of two parameter sets. This allows you to have two operating modes (RATE SET 0 or RATE SET 1) with independent ramp
parameters.
AUTO RESET 582 FALSE / TRUE
The ramp is reset automatically when the drive is enabled if set to TRUE.
EXTERNAL RESET 583 FALSE / TRUE
Resets the ramp output.

Table of Contents

Related product manuals