EasyManua.ls Logo

Parker 591C - Terminal Information (Option Boards

Parker 591C
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E-20 Technical Specifications 590 Series DC Digital Drive
Terminal Information – Control Board
This Control Board is common to all 590 units.
Terminal Description Terminal Function Signal Level Configurable Terminal
Number
+24V Supply
+24V Maximum output current: 250mA
Short circuit protected.
Up to 750mA only with AH385851 power board,
and only if LINK 24 is applied (shorting VP25 to
VP26, located above SW4 – 6 in the control
terminal area).
Applying LINK 24 disables short circuit protection.
Some typical loads are given below:
Microtach : 75mA
Relays : 50mA each
Fibre Optic ancillaries : 50mA each
N/A C9
Terminal Information (Option Boards)
Terminal Description Terminal Function Signal Level Terminal Number
TERMINAL BLOCK G (SWITCHABLE TACHO CALIBRATION OPTION)
+ AC Tacho input +AC G1
- AC Tacho input - AC G2
+ DC Tacho input +DC G3
- DC Tacho input - DC G4
(5701 MICROTACH RECEIVE OPTION - PLASTIC)
Signal Input Microtach fibre optic
input
There are no other connections to this option module. (The 5701 Microtach should be
powered by an external 24V DC at 60mA, 1.4W.)
F1

Table of Contents

Related product manuals