590 Series DC Digital Drive Operating the Drive
4-27
COMMS Control of the Drive
Remote Sequencing Command
REM. SEQUENCE : Tag 536, Mnemonic "ow", Default = 0x0000 ("0x" denotes a Hexadecimal value)
NOTE Refer to the RS485 Communications Interface Technical Manual, HA463560 on the website, for information about the EI Bisynch ASCII
communications protocol.
Reserved bits are undefined when read and should be set Zero when written.
Bit Number Mask Name Comment
0 (lsb) 0x0001 Remote Enable
1 0x0002 Remote Start
2 0x0004 Remote Jog
3 0x0008 Remote Jog Mode Selects Jog Speed
4 0x0010 Reserved
5 0x0020 Reserved
6 0x0040 Reserved
7 0x0080 Reserved
8 0x0100 Remote Alarm Ack Alarm Acknowledge
9 0x0200 Remote/Remote Trip Remote Trip (High for OK)
10 0x0400 Reserved
11 0x0800 Reserved
12 0x1000 Reserved
13 0x2000 Reserved
14 (msb) 0x4000 Reserved
15 (msb) 0x8000 Reserved