EasyManua.ls Logo

Parker 591C - Control Features

Parker 591C
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-6 Product Overview 590 Series DC Digital Drive
Control Features
Control
Control Circuits
Fully isolated from power circuit (SELV)
Output Control
Fully controlled 3-phase thyristor bridge
Microprocessor implemented phase control extended firing range
For use on 50 or 60Hz supplies with a frequency compliance range of 45 to 65Hz
Phase control circuits are phase rotation insensitive
Control Action
Fully digital
Advanced PI with fully adaptive current loops for optimum dynamic performance
Self Tuning Current Loop utilising "Autotune" algorithm
Adjustable speed PI with integral defeat
Speed Control
By Armature Voltage feedback with IR compensation
By Encoder feedback or analog tachogenerator
Speed Range
100 to 1 typical with tachogenerator feedback
Typical Steady State Accuracy
0.01 % Encoder Feedback with Digital setpoint (serial link or P3)
0.1 % Analog Tach Feedback
2 % Voltage Feedback
NOTE Long term analog accuracy is subject to tachogenerator temperature stability.
Adjustments
All adjustments in software can be altered by
the MMI or via serial communications. The MMI provides monitoring and adjustment of parameters and levels, in
addition to diagnostic facilities.
Protection
High energy MOVs
Overcurrent (instantaneous)
Overcurrent (inverse time)
Field failure
Speed feedback failure
Motor overtemperature
Thyristor Stack overtemperature (Force ventilated units)
Thyristor "Trigger" failure
Thyristor Snubber Network
Zero-speed detection
Standstill logic
Stall protection
Diagnostics
Fully computerised with first fault latch and automatic display
Digital LCD monitoring
LED circuit state indication
Table 2-1 Control Features

Table of Contents

Related product manuals