D-14 Programming 590 Series DC Digital Drive
ADVANCED
These two blocks perform some simple
functions. They are compatible with the special
Link 11 and Link12 used in earlier versions of
this product.
ADVANCED
Parameter Tag Range
INPUT 1 686, 688 -32768.00 to 32768.00 %
General purpose input.
INPUT 2 687, 689 -32768.00 to 32768.00 %
General purpose input.
ADVANCED 392, 397 OFF/ON
Controls the OUTPUT parameter. When OFF, OUTPUT is the same as INPUT 1. When ON, OUTPUT is the result of the function selected by
MODE.
MODE 393, 398 See below
This determines which operation is performed on the INPUT 1 and INPUT 2. It can be combined with ADVANCED to dynamically switch the
OUTPUT between INPUT 1 and the result of the selected function. The functionality of the various MODE selections are shown in the table.
0 : SWITCH
1 : INVERTER
2 : AND (logic)
3 : OR (boolean)
4 : SIGN CHANGER
5 : MODULUS
6 : COMPARATOR
OUTPUT 712, 713
.xx V
Result of the selected function on the inputs.