Operation
Operating Manual PSEN sc M 3.0/5.5 08-17
1005387-EN-05
| 105
Message in the display Error/cause Description/measure
Icon Text
INTF18 A device has been removed from the
arrangement of safety laser scan-
ners while the arrangement is in rest
condition or
Remove the device from the ar-
rangement according to the proced-
ure in Activate rest
condition [ 112].
An error occurred during the system
test.
Perform a reset of the safety laser
scanner [ 112].
If the error persists, please contact
Pilz.
INTF20 An error occurred in the connection
between the devices in a safety
laser scanner arrangement.
Check the network connections
between the devices in the arrange-
ment and the function of the sub-
scriber unit(s).
Perform a reset of the safety laser
scanner [ 112].
If the error persists, please contact
Pilz.
MG EMPTY No configuration is stored in the
memory module.
} Create a new configuration in
PSENscanConfigurator or
} Restore a configuration [ 111].
MG FAILURE The memory module is faulty or not
compatible with the current configur-
ation.
} Create a new configuration in
PSENscanConfigurator or
} Restore a configuration or
} Switch off the safety laser scanner
and replace the memory
module [ 69] with a new one.
MG NO
MATCHING
The memory module is not compat-
ible with the current configuration.
Switch off the safety laser scanner
and replace the memory
module [ 69] with a compatible
module.
OSSDF1 An error has occurred when testing
the OSSD1.
Check the EDM state and the wiring
of the OSSDs [ 64].
If the error persists, please contact
Pilz.
OSSDxF3 Overvoltage or an earth fault has oc-
curred on an OSSD1.
Check the EDM state and the wiring
of the OSSDs [ 64].
If the error persists, please contact
Pilz.
RES FAILED Restoring a configuration has failed.
} Restore a configuration [ 111]
or
} Create a new configuration in
PSENscanConfigurator [ 88].