Message in the display Error/cause Description/measure
Icon Text
SUB-
SCRIBER ER-
ROR
The master unit displays an error in
a subscriber unit.
11.3.2 Warnings
Message in the display Error/cause Description/measure
Icon Text
BOOTF An error has occurred when starting
the system.
Perform a reset of the safety laser
scanner [ 112].
If the error persists, please contact
Pilz.
INTF6 An error occurred during the system
test.
Perform a reset of the safety laser
scanner [ 112].
If the error persists, please contact
Pilz.
EXTTEMP The ambient temperature is outside
the temperature range indicated in
the Technical details.
Ensure that the ambient temperature
is in the temperature range specified
in the Technical details [ 127].
OVERTEMP The temperature of the safety laser
scanner is outside the permitted
temperature range.
Ensure that the temperature of the
safety laser scanner is within the
temperature range specified in the
Technical details [ 127].
HIGH REFL-
BKG
The reflection of the background is
too strong.
Reduce the background reflection or
increase the safety distance (see
Distance to intense light sources and
to reflective surfaces [ 50]).
11.3.3 Information
Message in the display Error/cause Description/measure
Icon Text
The wave function is activated. The symbol flashes. Select the
safety laser scanner in PSENscan
Configurator and configure it.
ANTITAM-
PERING
Protection against
manipulation [ 31] has been ac-
tivated.