Wiring
Operating Manual PSEN sc M 3.0/5.5 08-17
1005387-EN-05
| 71
Topology Point-to-point/hub
(hub, switch)
*1
For use in an industrial environment, Pilz recommends double-shielded twisted pair cables
(S/STP). Only shielded RJ45 connectors should be used.
*2
Twisted pair cables (TP cable) consist of twisted core-pairs. Twisted pair cables are divided
into categories in accordance with their electrical features (attenuation, cross-talk). Cat-
egory 5 cables are specified for transferring data with Pilz Ethernet interfaces.
TP cables for Ethernet applications generally have an impedance level of 100 Ohm.
7.8.1 Single connection
PSENscan Configurator
PSEN sc
Procedure:
1. Use a 4-pin cable (see Order references [ 135]) to connect the configuration PC to
the safety laser scanner.
2. Connect the safety laser scanner to the supply voltage and an evaluation
device [ 87].
Use an 8- or 17-pin cable or both cables (see Order references [ 135]).
3. Switch the safety laser scanner on.
4. Configure the safety laser scanner in PSENscan Configurator. [ 83]