EasyManuals Logo

Pilz PSEN sc M 3 Series User Manual

Pilz PSEN sc M 3 Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
Wiring
Operating Manual PSEN sc M 3.0/5.5 08-17
1005387-EN-05
| 68
Override
} When using the 17-pin connection and the 8-pin connection, the configurable inputs at
PIN 5, 6, 7, 9, 14 and 17 and PIN 8-1 to PIN 8-8 can be used for the following functions:
Restart
Reset
Restart or reset
If the safety laser scanner is in an error state, a reset is performed,
If the safety laser scanner is not in an error state, a restart is performed
EDM
Zone set switching
Muting 1 and 2
Dynamic activation of the muting state
Override
7.6 Wiring of the configurations
The wiring has to match the specifications in PSENscanConfigurator.
When an existing configuration is transferred to the safety laser scanner, the configurable
inputs/outputs must be wired in accordance with this configuration.
The configuration of the safety laser scanner PSEN sc M 3.0/5.5 08-17 series is carried out
in PSENscan Configurator on a configuration PC.

Table of Contents