Cleaning, checks and maintenance
Operating Manual PSEN sc M 3.0/5.5 08-17
1005387-EN-05
| 122
16. The OSSDs of the safety laser scanner switch to the OFF state.
Make sure that the danger zone cannot be used.
17. Switch the safety laser scanner on.
18. Click Reject or Accept to complete the calibration.
Click Accept to activate the downloaded configuration in the connected device and re-
ject the existing configuration on the connected device.
Click Reject to reject the downloaded configuration in the connected device and con-
tinue to use the existing configuration on the connected device. The downloaded con-
figuration in the connected device will be deleted.
19. The display of the safety laser scanner shows: COMMIT ON FIELD
20. In PSENscanī™Configurator select Device -> Exchange PSEN sc head.
Confirm the exchange of PSEN sc head with Finish.

Table of Contents