EasyManuals Logo

Polycom Vortex EF2241 User Manual

Polycom Vortex EF2241
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
B01AMCHNUM14
Set microphone 4 as the chairman mic
for automixer 1.
B01AMCHNUM14
B01AMCHNUM21
Set microphone 1 as the chairman mic
for automixer 2.
B01AMCHNUM21
B01AMCHNUM1?
Query the current chairman mic for
automixer 1.
B01AMCHNUM1x , where x is between 1 and 8
depending on the current chairman mic setting
for automixer 1.
8.16. AMDECAY -- Set Decay Time for Automixers
This command sets or queries the decay time (in milliseconds) for both automixers. Note that the decay time
is set globally for both automixers.
This command is an integer command. See
Section 6.2 for more information on this type of command. The
minimum and maximum values for this command are 0 and 5000, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
B01AMDECAY500
Set automixer decay time to 500
ms.
B01AMDECAY500
B01AMDECAY>500
Increase automixer decay time by
500 ms.
B01AMDECAYx , where x is between 0 and 5000
depending on the current AMDECAY setting. If this
command is issued after the above example, then
the status message will be B01AMDECAY1000
B01AMDECAY?
Query automixer decay time.
B01AMDECAYx , where x is between 0 and 5000
depending on the current AMDECAY setting. If this
command is issued after the above example, then
the status message will be B01AMDECAY1000
8.17. AMGATEC -- Set Automixer Gating Control Mode
This command sets the automixer gating control mode for the specified input channel. The possible modes
are:
0 - normal gating
1 - microphone forced on
2 - microphone forced off
This command is a channel integer command. See
Section 6.3 and Section 6.2 for more information on this
type of command. The minimum and maximum values for this command are 0 and 2, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message

Table of Contents

Other manuals for Polycom Vortex EF2241

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2241 and is the answer not in the manual?

Polycom Vortex EF2241 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2241
CategoryTelephone Accessories
LanguageEnglish

Related product manuals