EasyManuals Logo

Polycom Vortex EF2241 User Manual

Polycom Vortex EF2241
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
time it is changed. It will retain its value after power-down. Since this command writes to non-volatile
memory, there will be a delay before an acknowledgment is returned.
Example Description Status Message
B01FPLOCK1
Lock the front panel to prevent
users from changing the settings.
B01FPLOCK1
B01FPLOCK0,yumyum
Attempt to unlock the front panel by
using an invalid password
(yumyum).
B01ERROR#005 -- since an invalid password
was given, an error message was generated.
If error messages have been disabled (via the
ERROR command), then no status message
will be generated.
B01FPLOCK0,aspi
Unlock the front panel by using the
correct password.
B01FPLOCK0
B01FPLOCK?
Query the locked status of the front
panel.
B01FPLOCKx , where x is 0 or 1 depending
on whether the front panel is unlocked or
locked, respectively.
8.53. FPPSWD -- Change Front Panel Password
This command sets or queries the front panel password. This password is used in conjunction with the
FPLOCK command. The front panel must be unlocked ('FPLOCK0') in order to use this command to set or
query the front panel password. If the front panel is locked, then this command will result in 'ERROR#004'.
The examples below assume that the front panel is unlocked.
Example Description Status Message
B01FPPSWDmonkey
Set front panel password to 'monkey'.
B01FPPSWDmonkey
B01FPPSWD?
Query the current front panel password.
B01FPPSWDmonkey
8.54. GAINA -- Set Phone Input Gain
This command sets the gain of the incoming signal from the phone interface. This command is an alias for
the GAINIT command. It is provided for backwards compatibility with and ease of migration from the EF200.
When possible, the
GAINIT command should be used instead of this command.
This command is an integer command. See
Section 6.2 for more information on this type of command. The
minimum and maximum values for this command are -100 and 20, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
B01GAINA6
Set phone input gain to 6 dB.
B01GAINA6
B01GAINA>3
Increase phone input gain by 3 dB.
B01GAINAx , where x is the new value of the phone
input gain. If this command was issued after the
example above, then the status message would be
B01GAINA9 .

Table of Contents

Other manuals for Polycom Vortex EF2241

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2241 and is the answer not in the manual?

Polycom Vortex EF2241 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2241
CategoryTelephone Accessories
LanguageEnglish

Related product manuals