generated if a command attempts to exceend 100 percent utilization.
If the
DSPAUTO feature is enabled, then a DSPLOAD status message will be generated automatically any
time the percent utilization changes.
Example Description Status Message
B01DSPLOAD?
Query percentage of variable DSP
resources used.
B01DSPLOADx , where x is between 0 and 99
and indicates the percentage of the variable
DSP resources being used.
8.46. ERROR -- Enable or Disable Error Messages
This command sets or queries whether or not error messages for non-fatal errors are reported via RS-232
and the digital bus.
If an error is generated and error messages are enabled, a status message will be automatically generated of
the form ' B01ERROR#xxx ', where xxx is a three digit number indicating the error code. The following table
lists the non-fatal error messages that can be generated by the Vortex.
Error Number Description
ERROR#001
Unrecognized command.
ERROR#002
Syntax error in command.
ERROR#004
Attempt to change parameter that is locked via
NVLOCK or FPLOCK.
ERROR#005
Attempt to unlock
NVLOCK or FPLOCK, but invalid password given.
ERROR#040
This error occurs as the result of an
AMASGN command. It happens when the command
would remove a microphone from an automixer where it is assigned as the "last mic on"
and the automixer is set to manual "last mic on" mode.
ERROR#041
This error occurs as the result of an
AMASGN command. It happens when the command
would remove a microphone from an automixer where it assigned as the chairman
imcrophone and the automixer has chairman mode enabled.
ERROR#042
This error occurs as the result of an
AMLMM command. It happens when the command
attempts to set "last mic on" mode to manual, but the last mic number is set to a
microphone that does not belong to the specified automixer.
ERROR#043
This error occurs as the result of an
AMLMN command. It happens when the command
attempts to set a "last mic on" number that does not belong to the specified automixer
while "last mic on" mode is set to manual.
ERROR#044
This error occurs as the result of an
AMCHAIR command. It happens when the command
tries to enable chairman mode, but the chairman microphone is set to a microphone that
does not belong to the specified automixer.
ERROR#045
This error occurs as the result of an
AMCHAIR command. It happens when the command
tries to set the chairman microphone to a microphone that does not belong to the specified
automixer while chairman mode is enabled.

Table of Contents

Other manuals for Polycom Vortex EF2241

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2241 and is the answer not in the manual?

Polycom Vortex EF2241 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2241
CategoryTelephone Accessories
LanguageEnglish

Related product manuals