This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
B01AMHOLD500
Set automixer hold time to 500 ms.
B01AMHOLD500
B01AMHOLD>500
Increase automixer hold time by 500
ms.
B01AMHOLDx , where x is between 0 and 5000
depending on the current AMHOLD setting. If this
command is issued after the above example, then
the status message will be B01AMHOLD1000
B01AMHOLD?
Query automixer hold time.
B01AMHOLDx , where x is between 0 and 5000
depending on the current AMHOLD setting. If this
command is issued after the above example, then
the status message will be B01AMHOLD1000
8.22. AMLMM -- Set Last Mic On Mode for Specified Automixer
This command sets "last mic on" mode for the specified automixer. The first argument specifies which
automixer (1-2) The second parameter specifies the operation of "last mic on" mode and can be one of the
following:
0 - last mic mode is off
1 - manual (use a specific mic)
2 - automatic (the last gated mic remains on)
If the AMLMM command sets "last mic on" mode to manual, but the last mic number (
AMLMN) is set to a
microphone that does not belong to the specified automixer, then the AMLMM command will fail and
ERROR#042 will be generated. See the
ERROR command for more information on error messages. See
Section 3.5 for more information on dependencies within the automixer commands.
Even though this is a channel integer command, use of the wildcard character for specifying the automixer
number is not supported.
This command is a channel integer command. See
Section 6.3 and Section 6.2 for more information on this
type of command. The minimum and maximum values for this command are 0 and 2, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
B01AMLMM10
Disable "last mic on" mode for automixer 1.
B01AMLMM10
B01AMLMM21
Set "last mic on" mode to manual for
automixer 2 .
B01AMLMM21
B01AMLMM12
Set "last mic on" mode to automatic for
automixer 1.
B01AMLMM12

Table of Contents

Other manuals for Polycom Vortex EF2241

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2241 and is the answer not in the manual?

Polycom Vortex EF2241 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2241
CategoryTelephone Accessories
LanguageEnglish

Related product manuals